    摘要:

    以牛腱子肉为研究对象,通过不同真空卤煮、不同超声功率协同真空卤煮、不同超声频率协同真空卤煮3种卤煮方式卤制牛肉,测定卤煮过程中卤牛肉的食盐、水分和重量变化,研究超声波协同真空卤煮牛肉的传质规律。结果表明:食盐含量变化随着真空度、超声波功率和频率的增加而增大,水分含量变化与重量变化随着真空度、超声波功率和频率的增加而减小。卤煮过程中卤牛肉食盐含量变化的动力学参数k1、k2与真空度、超声功率和频率的大小有关;真空度-0.043 MPa、超声波频率28KHz、功率1000 W下,食盐含量变化的有效扩散系数De值最大,为1.42×10-4 m2/s,3种卤煮方式的传质驱动力与t0.5 /l 具有很好的线性关系。真空卤煮与超声协同真空卤煮对卤牛肉的微观结构有显著影响。因此,超声协同真空卤煮对卤牛肉中的传质有显著影响,能促进传质进程,超声波协同真空卤煮最佳传质条件为真空度-0.043 MPa,超声频率28 KHz,超声功率1000 W,超声时间30min。

    Abstract:

    Beef shank meat was taken as the research object, and the beef was braised by 3 braising methods, namely different vacuum braising, different ultrasonic power synergistic vacuum braising and different ultrasonic frequency synergistic vacuum braising, while the salt, moisture and weight changes of the braised beef were measured during the braising process to research the mass transfer law of ultrasonic co-vacuum braised beef. The results show that salt content variation increase with the increase of vacuum degree, ultrasonic power and frequency, moisture content variation and weight variation decreasing with the increase of vacuum degree, ultrasonic power and frequency. Kinetic parameters k1, k2 of the salt content variation of brined beef during braising process are in relation to vacuum degree, ultrasonic power and frequency. Under the conditions of vacuum degree -0.043 MPa, ultrasonic frequency of 28 KHz and power of 1000 W, the maximum value of effective diffusion coefficient De of salt content variation is 1.42×10-4 m2/s. The mass transfer driving force of 3 braising methods has a positive linear relationship with t0.5 /l, the correlation coefficients were all good. Vacuum braising and ultrasonic synergistic vacuum braising have significant effects on the microstructure of brined beef. Therefore, ultrasonic synergistic vacuum stewing has a significant effect on the mass transfer in stewed beef and can promote the mass transfer process. The best mass transfer conditions for ultrasonic synergistic vacuum stewing are vacuum degree -0.043 MPa, ultrasonic frequency 28 kHz, ultrasonic power 1000 W and ultrasonic time 30 min.

    参考文献
    相似文献
    引证文献
引用本文
相关视频

分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2021-11-22
  • 最后修改日期:2022-01-30
  • 录用日期:2022-02-12
  • 在线发布日期:
  • 出版日期:
文章二维码
×
因办公室装修,期间暂时无法接听电话,如有事请QQ或邮件联系。信息咨询:QQ: 2553003667稿件处理1:QQ: 1542354573稿件处理2:QQ: 2195608851 财务咨询:QQ: 1347040116 Email:mfood@scut.edu.cn、mfood@foxmail.com